User manual LIFT-MASTER SL3000UL
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LIFT-MASTER SL3000UL. We hope that this LIFT-MASTER SL3000UL user guide will be useful to you.
Manual abstract: user guide LIFT-MASTER SL3000UL
Detailed instructions for use are in the User's Guide.
[. . . ] ®
TM
Instruction
Manual
SL3000ULTM SERIES
H I G H T R A F F I C C O M M E R C I A L G AT E O P E R AT O R
UL325 UL991
compliant compliant
LISTED
installation instructions and manual book for architects, general contractors and dealers
© 2005 the chamberlain group, inc. all rights reserved
S L 3 0 0 0 U LTM
Overview
Limit Switch Box Pg. 20 Motor Capacitor Motor Interlock Assembly Drive Belt EMERGENCY RELEASE Pg. 28 Optional Factory Installed DC2000 Battery Back-Up Motor Models DC and DCH Only Radio Receiver Pg. 27 Gear Reducer
Cover
Built-In Reset Button Pg. 24 EMERGENCY RELEASE Crank Tool Pg. 28 Crank Tool Housing Pg. 28 Radio Receiver Antenna
Chassis
Limit Switch Chain Sprocket
Operator ON OFF Switch Control Box
OFF
ON
Limit Switch Chain Drive Sprocket Optional Factory Installed Heater Models H and DCH Only Pg. 33 Idler Wheels Optional Factory Installed DC2000 Battery Back-Up Controller Models DC and DCH Only Pg. 30
®
W4
Optional Plug-In Loop Detectors Pg. 39 OmniControlTM Board Surge Suppressor Terminal Pg. 19 UL Alarm Pg. 25 DC2000 Harness Pg. 30 SL Power Wires Pg. 18
N IO AC V UT20eutrald 1 CAck e NGroun la
B hit n W ree G
TM
LISTED
1
TABLE
OF
CONTENTS
Safety Instructions
Role of Specifiers and Designers Role of Dealers, Installers and Trained Gate System Technicians Role of End Users / Home Owners Horizontal Slide Gate Systems UL Listings Warnings and Precautions 4 4 5 5 6-9 10
Installation
Recommended Setup and Operator Specifications Gate Post Warning Mounting Required Warning Signs Types of Installation Connecting the Chain Concrete Pad and Gate Attachment Gate and Operator Mounting Distance Optional Post Mounting Plate How to Connect Power (110 V) Surge Suppressor Terminal Input Connections (Wiring Optional Equipment) Choosing Gate Movement Direction (Open Left or Right) Adjusting Gate Traveling Distance (Limit Switches) Two-Way Adjustable Reversing Sensor Adjustable Timer Master / Second Operators with Timer On Master / Second Operators with Timer Off Built-In Reset Button Remove Control Board Audio Alarm Solenoid/Maglock J3 Plug Connection Radio Receiver Programming 11 12 13 14 15 15 16 17 18 19 20 20 21 21 22 23 24 25 25 26 27
Table Of Contents
EMERGENCY RELEASE
Optional Emergency Release
Please DO NOT Touch me!. . Unless you are an Authorized Service Technician!
© 2005 The Chamberlain Group, Inc.
All Rights Reserved.
28
29
For Technical Support: 1-800-528-2806
2
TABLE
OF
CONTENTS
Optional Factory Installed Equipment
Optional Factory Installed DC2000 Back-Up Connection. Models DC and DCH Only Wiring Optional Devices to DC2000 Wiring Optional Safety Devices to DC2000 Optional Factory Installed Heater. [. . . ] All other terminals will only open with a single push of a button.
8 7
Fire or Any Key Switch
19
CHOOSING
GATE
MOVEMENT
DIRECTION
Open to the Left
Open to the Right
Choosing Gate Movement Direction
OU T
IN
OU
T
OPEN LEFT
DC-BACKUP
RADIO
W4 GBA
MS LINK
SENSOR ALARM
REVERSE SENSOR
ALARM SENSOR
OFF
OPEN LEFT
ON
OPEN RIGHT
OPEN
EXIT
COMMAND PROCESSED
CENTER SAFETY
FIRE DEPT.
STRIKE OPEN
RADIO RECEIVER
GATE LOCKED
EXIT LOOP
SAFETY LOOP
CENTER LOOP
RESET MOTOR
ADJUSTING
GATE
TRAVELING
CLOSE
STOP
IN
MER 60 MER 60
1 3
CENTER SAFETY EXIT
1
3
OFF
ON
OPEN RIGHT
OFF
OPEN LEFT
ON
OPEN RIGHT
SENSORS
SYSTEM ON
TIMER 60 3
POWER OVERLOAD
RADIO
1
3
MADE IN USA
1
3
1
3
DISTANCE
Adjusting Gate Traveling Distance
Nut
Push Plate
Limit Nut Lock Plate
Each notch is an estimated 1 inch of gate travel.
Before Adjusting, Do the Following: 1. If you need more adjusting, repeat the process.
2-WAY
ADJUSTABLE
REVERSING
SENSOR
Adjusted by Qualified Service Personnel
CENTER SAFETY EXIT
2-Way Adjustable Reversing Sensor
DC-BACKUP
W4 GBA
MS LINK
SENSORS
SYSTEM ON
TIMER 60 3
POWER OVERLOAD OPEN
REVERSE SENSOR
ALARM SENSOR
1
3
OFF
OPEN LEFT
ON
OPEN RIGHT
1
3
1
3
EXIT
COMMAND PROCESSED
CENTER SAFETY
FIRE DEPT.
STRIKE OPEN
RADIO RECEIVER
GATE LOCKED
CLOSE
STOP
SENSOR ALARM
3
1
3
MADE IN USA
EXIT LOOP
SAFETY LOOP
CENTER LOOP
RESET MOTOR
DO NOT TOUCH ALARM SENSOR
CAUTION: If the power supply to the gate operator is less than 99 volts, adjust the alarm by turning the alarm adjustment counter-clockwise enough to actuate the alarm when obstructed but not sensitive enough for false triggering to occur.
The level of reverse sensitivity depends on the Minimum weight of the gate and the condition of Sensitivity installation. To make a better gate system, use any of Chamberlain Elite's power wheels. Not sensitive enough = if the gate hits a vehicle and does not stop or reverse.
ADJUSTABLE
TIMER
TIMER
NSOR
CENTER SAFETY EXIT
60
3
REVERSE SENSOR
Maximum Sensitivity
Timer ON
Set Timer 1 to 60 seconds
Adjustable Timer
OFF
OPEN LEFT
ON
1
3
OPEN RIGHT
DC-BACKUP
W4 GBA
MS LINK
SENSORS
SYSTEM ON
TIMER 60 3
POWER OVERLOAD
SENSOR ALARM
REVERSE SENSOR
ALARM SENSOR
1
3
OFF
OPEN LEFT
ON
OPEN RIGHT
MADE IN USA
1
3
1
3
TIMER
NSOR
OPEN
EXIT
COMMAND PROCESSED
CENTER SAFETY
FIRE DEPT.
STRIKE OPEN
RADIO RECEIVER
GATE LOCKED
EXIT LOOP
SAFETY LOOP
CENTER LOOP
RESET MOTOR
CLOSE
STOP
60
3
OFF
OPEN LEFT
1
3
ON
OPEN RIGHT
Timer can be set from 1 to 60 seconds (Timer ON), OR for push open/push close type operation (Timer OFF).
Timer OFF
Note: When using master/second gates, the gate that takes the longest to open should be set as the master.
21
MASTER/SECOND
Master Omni Board Primary Control for System
WITH
TIMER
ON
Master and Second Boards are Interchangeable
Caution: Never run high voltage and low voltage wires in same conduit
Master / Second with Timer ON
Use low voltage wires in separate conduit to connect gate operators together Note: The gate that takes the longest to open should be set as the master.
CENTER SAFETY EXIT
Master Omni Board TIMER
SENSOR ALARM
60
3
NSOR
DC-BACKUP
OFF
OPEN LEFT
ON
1
3
Adjust Time Desired 0 to 60 seconds
CENTER
W4 GBA
MS LINK
SENSORS
SYSTEM ON
TIMER 60 3
POWER OVERLOAD OPEN
OPEN RIGHT
REVERSE SENSOR
ALARM SENSOR
1
3
OFF
OPEN LEFT
ON
OPEN RIGHT
Second Omni Board
SAFETY EXIT
MADE IN USA
1
3
1
3
EXIT
COMMAND PROCESSED
CENTER SAFETY
FIRE DEPT.
STRIKE OPEN
RADIO RECEIVER
GATE LOCKED
EXIT LOOP
SAFETY LOOP
CENTER LOOP
RESET MOTOR
CLOSE
STOP
®
OmniControl Surge Suppressor
P/N Q410 Patent Pending
Master Timer "ON"
+
DC-BACKUP
W4 GBA
MS LINK
SENSORS
SYSTEM ON
TIMER 60 3
POWER OVERLOAD OPEN CLOSE STOP
REVERSE SENSOR
ALARM SENSOR
1
3
OFF
OPEN LEFT
ON
OPEN RIGHT
1
3
1
3
COMMAND PROCESSED
Class 2 Supply
24 Volts DC
EXIT
M/S Link
CENTER SAFETY
G
B
A
Center Loop
Safety Loop
Exit Loop
Fire Dept Key Switch
Strike Open Push Button
Radio Receiver
FIRE DEPT.
STRIKE OPEN
RADIO RECEIVER
GATE LOCKED
EXIT LOOP
SAFETY LOOP
CENTER LOOP
RESET MOTOR
®
OmniControl Surge Suppressor
P/N Q410 Patent Pending
+ Radio Receiver
Class 2 Supply
24 Volts DC
G
B
M/S Link
A
Use Shielded Twisted Wires to Connect the Surge Suppressor of each Gate Operator Together
P/N Q410 Patent Pending
Center Loop
Safety Loop
Exit Loop
Fire Dept Key Switch
Strike Open Push Button
P/N Q410 Patent Pending
G
B
M/S Link
A
Center Loop
G
B
M/S Link
A
Center Loop
MAXIMUM Counterclockwise Setting
CHASSIS GROUND
CHASSIS GROUND
1. Connect G from the master surge suppressor to G of the second surge suppressor. Connect B from the master surge suppressor to B of the second surge suppressor. Connect A from the master surge suppressor to A of the second surge suppressor. Use MASTER timer ONLY to select the desired time
TIMER
60
3
NSOR
OFF
OPEN LEFT
ON
1
3
OPEN RIGHT
Second Timer "ON"
22
SENSOR ALARM
MADE IN USA
MASTER/SECOND
WITH
TIMER
OFF
Caution: Never run high voltage and low voltage wires in same conduit
Use low voltage wires in separate conduit to connect gate operators together
CENTER
Master Omni Board
SAFETY EXIT
CENTER
SAFETY
Second Omni Board
EXIT
Master / Second with Timer OFF
TIMER
SENSOR ALARM DC-BACKUP
60
3
DC-BACKUP
W4 GBA
MS LINK
W4 SYSTEM ON GBA TIMER 60 3 POWER OVERLOAD OPEN
NSOR
SENSORS
REVERSE SENSOR
REVERSE SENSOR
ALARM SENSOR
ALARM SENSOR
1
3
OFF
OPEN LEFT
ON
OPEN RIGHT
OFF
OPEN LEFT
ON
OPEN RIGHT
MADE IN USA
OPEN
OFF
OPEN LEFT
1
3
MS LINK
SENSORS
SYSTEM ON
TIMER 60 3
ON
EXIT CENTER SAFETY
POWER OVERLOAD
1
3
1
3
1
3
1
3
1
3
EXIT
STOP
COMMAND PROCESSED
CENTER SAFETY
FIRE DEPT.
STRIKE OPEN
RADIO RECEIVER
GATE LOCKED
COMMAND PROCESSED
FIRE DEPT.
STRIKE OPEN
RADIO RECEIVER
GATE LOCKED
CLOSE
EXIT LOOP
SAFETY LOOP
CENTER LOOP
RESET MOTOR
OPEN RIGHT
EXIT LOOP
SAFETY LOOP
CENTER LOOP
RESET MOTOR
®
OmniControl Surge Suppressor
P/N Q410 Patent Pending
®
OmniControl Surge Suppressor
P/N Q410 Patent Pending
+ Radio Receiver
Class 2 Supply
24 Volts DC
+ Radio Receiver
Class 2 Supply
24 Volts DC
G
B
M/S Link
A
Center Loop
Safety Loop
Exit Loop
Fire Dept Key Switch
Strike Open Push Button
G
B
M/S Link
A
Center Loop
Safety Loop
Exit Loop
Fire Dept Key Switch
Strike Open Push Button
Use Shielded Twisted Wires to Connect the Surge Suppressor of each Gate Operator Together
P/N Q410 Patent Pending
P/N Q410 Patent Pending
G
B
M/S Link
A
Center Loop
G
B
M/S Link
A
Center Loop
TIMER
NSOR
60
3
CHASSIS GROUND
CHASSIS GROUND
OFF
OPEN LEFT
1
3
ON
OPEN RIGHT
1. Connect G from the master surge suppressor to G of the second surge suppressor. Connect B from the master surge suppressor to B of the second surge suppressor. Connect A from the master surge suppressor to A of the second surge suppressor. Turn timers on BOTH Omni boards to the "OFF" position
PARTIAL
MASTER/INDIVIDUAL
CONTROL
In order for the following operation to occur, follow the instructions. Example: There is a double gate, the entry gate is to be opened with a radio transmitter and the exit gate with a free exit loop. Only one safety loop system is to open both gates, and a fire department switch should open both gates at the same time. (Observe polarity of both operators)
23
CLOSE
STOP
SENSOR ALARM
MADE IN USA
BUILT-IN
RESET
BUTTON
Built-In Reset Button
When the gate operator's audio alarm (See next page) has been tripped, the Reset Button must be pushed for the operator to function again.
The Reset Button will shut off an activated audio alarm and reset the operator to function again.
If the audio alarm goes off, always check the gate area for: · Obstructions in the gate path. · Damage to the gate and/or gate operator.
Pressing the Reset Button will stop a moving gate during a normal open/close cycle, like a stop button. The operator does NOT need to be reset after doing this.
24
REMOVE
CONTROL
BOARD
OFF
OFF
ON
ON
Remove Control Board
W4
W4
Disconnect wire harnesses from OmniControl board. Unscrew 3 nuts and remove board.
AUDIO
ALARM
When one of the following events happens Twice Consecutively, the Alarm will Sound for 5 minutes!
Press the Built-In Reset Button to Shut Off Alarm and Reset Operator!(See previous page)
1 The gate is too heavy.
Audio Alarm
2 Debris is on the gate's track such as mud, rocks, dirt, etc.
3 The gate is hitting a wall or vehicle.
4 The gate has one or more broken wheels.
5 A moving vehicle has hit the gate and the wheel is off the track.
25
SOLENOID/MAGLOCK
J3
CONNECTION
2 4
CENTER SAFETY EXIT
1 3 5 7 9
J3
Normally Closed Common
6 8 10
SENSOR ALARM
Solenoid / Maglock J3 Connection
Normally Open Connection of a Solenoid or Magnetic Lock can be made using the J3 plug and three wires supplied with the unit.
Relay Contact Rating
0. 5 A - 125 Vac 1 A - 24 VDC
DC-BACKUP
W4 GBA
MS LINK
SENSORS
SYSTEM ON
TIMER 60 3
POWER OVERLOAD OPEN CLOSE STOP
REVERSE SENSOR
ALARM SENSOR
1
3
OFF
OPEN LEFT
ON
OPEN RIGHT
MADE IN USA
1
3
1
3
EXIT
COMMAND PROCESSED
CENTER SAFETY
FIRE DEPT.
STRIKE OPEN
RADIO RECEIVER
GATE LOCKED
EXIT LOOP
SAFETY LOOP
CENTER LOOP
RESET MOTOR
Solenoid Lock
2 4 6 8 10 1 3 5 7 9
#7 Common
Solenoid Lock
J3
#3 Normally Closed
Ground Plug-In Transformer
Wire Nut
Insert 2 supplied wires into J3 plug (#3 and #7) (Motor Harness)
Power Ground
Magnetic Lock
Magnetic Lock
2 4 6 8 10
1 3 5 7 9
J3
Insert 2 supplied wires into J3 plug (#7 and #8) (Motor Harness) #7 Common
Ground
Plug-In Transformer
Wire Nut Power Ground
#8 Normally Open
26
RADIO
RECEIVER
PROGRAMMING
Note: Hand Held Remote NOT Included with Gate Operator.
Radio Receiver Programming
Up to 31 Security Plus, Passport remotes or unlimited dip switch remotes can be used.
Programming Radio Receiver:
Press and Release the "Learn Button". Within that time, press a desired button on your hand held remote for 3 seconds to program the radio receiver. Repeat this process for every hand held remote to be used with the gate operator.
Erase ALL Remote Control Codes:
Press and Hold the "Learn Button" until LED turns off (6 seconds). All codes are now erased.
Optional Hand Held Remotes
Part # 971LM
Part # CPT1
Part # 972LM
Part # CPT2
Mini 3 Button Part # 970LM
l ona Optiducts Pro
Part # 973LM Part # CPT3
Mini 3 Button Part # CPTK3
Part # 974LM
Part # CPT4
Mini 3 Button with HID Prox. [. . . ] Reset the motor
Overload LED On and Power LED On System On LED Flashing
1. Alarm sensor is extra sensitive
Troubleshooting Table
Reverse Sensor LED On
1. Turn the reverse sensor switch counter clockwise a little more and try again 1. Turn the alarm sensor switch counter clockwise a little more and try again
Alarm Sensor LED On
Command Processed LED On
1. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE LIFT-MASTER SL3000UL