User manual LIFT-MASTER ROBO SLIDE
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LIFT-MASTER ROBO SLIDE. We hope that this LIFT-MASTER ROBO SLIDE user guide will be useful to you.
Manual abstract: user guide LIFT-MASTER ROBO SLIDE
Detailed instructions for use are in the User's Guide.
[. . . ] copyright © 2004 chamberlain professional products - www. eliteaccess. com
TABLE
OF
CONTENTS
2 3 4-6 7 8 9 10 10 11 11 12 13 14 15 16 17 17 18 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33-34 35 35 36 36 37 38 39 40 41
Role of Specifiers. . . , Role of Dealers. . . . Role of End Users/Home Owners, Horizontal Slide Gate Systems Warnings and Precautions Safely Operating Gate Important Notice Configuration and Specifications Warnings and Precautions Step 1: Getting Started Step 2: Mounting Operator Step 3: Chain Installation Step 4: Gate Movement Direction Step 5: Earth Ground Rod Step 6: DC Power Supply Connection Step 7: "Optional" Solar Panel Step 8: Surge Suppression Terminal Connections Step 9: Adjusting Gate Travel Distance Step 10: Timer Step 11: 2-Way Adjustable Reversing Sensor Step 12: Mounting Warning Placards "Optional" Fire Release Box "Optional" Input Board Maglock Wiring Connection "Optional" 12 VDC Photocell Wiring 3-Push Button Wiring Connection 3-Push Button Wiring Master / Slave "Optional" Edge Sensor Wiring Single Operator Loop Size and Placement Master / Slave Loop Size and Placement Loop Installation and Number of Wire Turns Wiring Loop Detector to Operator Master and Slave Operators with Timer Master and Slave Operators without Timer Control Board Functions LED Descriptions Troubleshooting How to Reset Breaker Switch How to Check Fuses Gate will not close!If you hear a "BEEP" sound (Audio Alarm) Robo Slide Parts Robo Slide Parts List Elite Robo Slide Accessories Owners Checklist of Installation
Please DO NOT Touch me!. . Unless you are an Authorized Service Technician!
© COPYRIGHT 1992-2003 BY ELITE ACCESS SYSTEMS, INC. [. . . ] After the beeps, check the "Charge OK" LED. . . . . . it must be "ON".
Motor Harness
Alarm Sensor LED will flash 3 times during power connection. This means the board is OK.
CHECK
CHARGINGFUSE BOARD POWER POWER
Beep!Beep!
SYSTEM ON
J2
ALARM SENSOR
REVERSE SENSOR
OVERLOAD
HEAVY GATE
POWER
CHARGE OK
BATTERY LOW OPEN RELAY CLOSE RELAY
DC OPERATOR v 5M MADE IN USA
Battery Connected Only: Power LED on Transformer Connected Only: Power LED on Charge OK LED on
CENTRAL CONT
FIRE DEPT
ROL
OPEN
STRIKE OPEN
STOP
TIMER
ON
UP
PW
SAFETY LOOP EXIT LOOP RADIO REC
60 OFF
0
CLOSE
14
STEP
BY
STEP
INSTALLATION
STEP 7: Optional Solar Panel Connection
If you use Elite's optional solar panel (Elite Part # Solar 3). Connect the two wires from the solar panel to the power input connection on the surge suppressor (Polarity does not matter). This solar panel will charge up to 1000 Mamp/Hr in optimum conditions & 300 Mamp/Hr in light overcast conditions. For further details about Elite's solar panel, consult the "Solar 3" Installation sheet that is included with the solar panel.
® ®
CAUTION
Do Not use solar panel and plug-in transformer at the same time.
AC AC
ACCESS SYSTEMS INC
R
Solar Panel
(Elite Part # SOLAR 3) No Stand
POWER INPUT 18 VAC
® ®
AC AC
ACCESS SYSTEMS INC
ROBO SURGE SUPPRESSOR PATENT P/N Q412 PENDING 7 8 9 10 11 12 13 1456
+ RADIO RECEIVER
Polarity Does Not Matter
POWER INPUT 18 VAC
SAFETY LOOP
EXIT LOOP
FIRE DEPT STRIKE OPEN KEY SWITCH PUSH BUTTON
CLASS 2 SUPPLY
Energizing this operator with solar power only needs the radio receiver to operate the gate. The only recommended external devices other than radio receivers are dry-contact command devices which do not consume any current like key switches. Using other devices that consume high current such as telephone access, magnetic locks or loop detectors will cause excess drainage of the battery and eventually completely drain the battery . Elite recommends using a larger battery (12 VDC, 30 AHr) (Elite Part # A 12330) in this operator when using the optional solar panel.
CAUTION
12 VDC r 30 AH
For More Details, contact your Local Dealer 15
STEP
BY
STEP
INSTALLATION
STEP 8: Surge Suppressor Terminal Connections
The radio receiver must be 12 VDC only (Elite Part # A 1099-12V). If you want to use safety or exit loops, you must use 12 VDC loop detectors only (Elite Part # A 23).
® ®
AC AC
ACCESS SYSTEMS INC
ROBO SURGE SUPPRESSOR PATENT P/N Q412 PENDING 7 8 9 10 11 12 13 1456
POWER INPUT 18 VAC SAFETY LOOP EXIT LOOP FIRE DEPT STRIKE OPEN KEY SWITCH PUSH BUTTON
+ RADIO RECEIVER
CLASS 2 SUPPLY
4 Wire -12 VDC Radio Receiver To 115 VAC
Polarity does NOT Matter
13 12 11 11
+ Red Radio (+12 VDC)
Grey Radio (Relay)
Black Radio (-) Grey Radio (Relay)
AC AC
Plug-In Transformer 18 VAC
1 4
External "Safety" Loop Detector 12 VDC
10 9
Card Reader
10 9
Push Button
1 4
Photo Beam (Safety) 12 VDC
10 9
Phone Entry
1 4 7
HELP
2 5 8 0
3 6 9
5 6
External "Exit" Loop Detector 12 VDC
8 7
Fire or Any Key Switch
16
STEP
BY
STEP
INSTALLATION
STEP 9: Adjusting Gate Travel Distance
Adjustment is done by limit switches which are located on the Robo Slide chassis. By pressing the plate down and spinning the adjustment nuts, set your limit switches for open and close cycles.
Limit Switches
Each notch of the nut indicates an estimated 1 inch of gate travel
STEP 10: Timer
If you want to use the automatic close for the gate system, the timer switch should be set to the "ON" position. If you want to use the push open or push close command, the timer should be set to the "OFF" position.
CHECK
CHARGINGFUSE BOARD POWER POWER
SYSTEM ON
TIMER
Set Timer 0 to 60 seconds
UP
PW
STOP
OVERLOAD POWER
J2
ALARM SENSOR
REVERSE SENSOR
ON 60
OFF
HEAVY GATE
0
CLOSE
CHARGE OK
BATTERY LOW OPEN RELAY CLOSE RELAY
DC OPERATOR v 5M MADE IN USA
CENTRAL CONT
FIRE DEPT
ROL
OPEN
STRIKE OPEN SAFETY LOOP EXIT LOOP RADIO REC
ON 60 OFF 0
TIMER
ON
UP
PW
STOP
OPEN TO RIGH T
60
0
CLOSE
OFF
17
W1
CLOSE
STOP
TIMER
UP
PW
STEP
BY
STEP
INSTALLATION
STEP 11: Two-Way Adjustable Reversing Sensor
Adjust the "Reverse Sensor" pot on the upper portion of the control board. The level of reverse sensitivity depends on the weight of the gate and the condition of installation. Not sensitive enough = if the gate hits an object and does not stop or reverse.
Do Not Touch Alarm Sensor Pot
Minimum Sensitivity
HEAVY GATE
CHECK
CHARGINGFUSE BOARD POWER POWER
SYSTEM ON
J2
Important Note!
There is a "Heavy Gate" LED which will light up when the gate is heavier than normal. This is a diagnostic LED and the operator will still function normally when this indicator is on.
SYSTEM ON
ALARM SENSOR
ALARM SENSOR
REVERSE SENSOR
OVERLOAD POWER
CHARGE OK
HEAVY GATE
BATTERY LOW
REVERSE SENSOR
OPEN RELAY CLOSE RELAY
DC OPERATOR v 5M MADE
IN USA
CENTRAL CONTRO
FIRE DEPT STRIKE OPEN
L
STOP
TIMER ON
UP
PW
SAFETY LOOP EXIT LOOP RADIO REC
60 OFF
0
CLOSE
OPEN TO RIGHT
Maximum Sensitivity
STEP 12: Warning placards need to be permanently mounted on BOTH sides of the gate.
W1
OPEN
NOW YOUR INSTALLATION IS COMPLETE
18
For Toll Free Technical Support: 1-888-ELITE-10
35483
"OPTIONAL"
FIRE
RELEASE
BOX
The "Fire Release Box", is designed for use on sliding gates. The doors can be locked with your own padlock, or the fire department's padlock. A steel cable with a t-handle runs from the box to the release mechanism at the rear end of the chain. The release mechanism, is placed where the chain bolt would normally be. To reset, simply reinsert the pin into the housing for normal operation. (Elite Part # A CP-17)
Pull firmly on the "T" Handle to release the chain.
Contact your local dealer for more information.
The chain is held in place by a spring loaded pin. 19
"OPTIONAL"
INPUT
BOARD
The optional board allows extra control of the gate, is available only from Elite Access Systems. Installation is simple; just clip the optional board to the J2 slot on the top of the control board. [. . . ] Low battery Open relay is energized Close relay is energized
If dimmed down 1. Bad Charging power fuse
3 Battery Low
normally off - it will indicate low battery
Battery OK Battery voltage is over minimum required limit
4 Heavy Gate
will work only when the gate is in motion
Gate weight and condition are OK
5 Open Relay 6 Close Relay 7 System On
Open relay is not energized Close relay is not energized 1. No motor current detected
will work only when the gate is in motion
8 Alarm Sensor
Detecting motor current
when LED goes on you will hear a "beep" sound for about 20 seconds LED will flash 3 times for "board OK" during power connection.
1. Unwanted object has physically stopped gate
System is OK
Note: Circled red numbers indicates location on control board, identified on page 32.
33
LED
DESCRIPTION
LED On
-
CONTINUED
LED Off
No obstruction is detected
LED Description
9
Reversing Sensor
Sensor is detecting obstruction
10 Central Control
Acknowledgement of receiving open command from one of the surge suppressor terminals · Fire Department 7 & 8 · Strike Open 9 & 10 · Safety Loop 1&4 · Exit Loop 5&6 · Radio Receiver 11 & 12 Receiving signal at the surge suppressor terminal block 7&8 Receiving signal at the surge suppressor terminal block 9 & 10 Receiving signal at the surge suppressor terminal block 1&4 Receiving signal at the surge suppressor terminal block 5&6 Receiving signal at the surge suppressor terminal block 11 & 12
Not receiving any command
11 Fire Dept
Not receiving signal at the surge suppressor terminal block 7 & 8 Not receiving signal at the surge suppressor terminal block 9 & 10 Not receiving signal at the surge suppressor terminal block 1 & 4 Not receiving signal at the surge suppressor terminal block 5 & 6 Not receiving signal at the surge suppressor terminal block 11 & 12
12 Strike Open
13 Safety Loop
14 Exit Loop
15 Radio Rec
16 Timer PW
Timer power is on
Timer is not on
17 Timer UP
Output signal to close relay
Not receiving signal to close relay
Note: Circled red numbers indicates location on control board, identified on page 32.
34
TROUBLESHOOTING
How to Reset the Breaker
If all electronic sensors fail or are not adjusted properly due to heavy gates, off-track gate, or obstructed gate path, the breaker will kick-out. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE LIFT-MASTER ROBO SLIDE
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LIFT-MASTER ROBO SLIDE will begin.