[. . . ] Robo Swing R900TM / Robo SlideTM
surge suppression installation manual
Please read this entire manual before installation
Important!
Possible Damage
50 ft
ROBO SURGE SUPPRESSOR
P/N Q412 PATENT PENDING
The green ground wire must be securely connected to the chassis
Note: Plate For Use with Roboswing Only!
ACCESS SYSTEMS INC
Safe
+ POWER INPUT 18 VAC SAFETY LOOP EXIT LOOP FIRE DEPT STRIKE OPEN KEY SWITCH PUSH BUTTON RADIO RECEIVER
CLASS 2 SUPPLY
50 ft
Inputs protected by the Surge Protection Module. [. . . ] All Rights Reserved
For Technical Support: 1-800-528-2806
TM 845 Larch Avenue Elmhurst, Illinois 60126 www. chamberlain. com
W1
CHECK
CHARGING FUSE BOARD POWER POWER
SYSTEM ON
J2
ALARM SENSOR REVERSE SENSOR
OVERLOAD POWER
CHARGE OK BATTERY LOW OPEN RELAY CLOSE RELAY
HEAVY GATE
DC OPERATOR v 5M MADE IN USA
CENTRAL CONTROL
FIRE DEPT STRIKE OPEN
TIMER ON
UP
PW
SAFETY LOOP
60 OFF
0
EXIT LOOP RADIO REC
OPEN TO
RIGHT
W1
Robo SlideTM Surge Suppressor Step-by-Step Installation
STEP 1 STEP 2
Unplug the power transformer, battery connection and all accessory wires from terminal block.
CAUTION!
gate catch post warning
Disconnect yellow power transformer wires from J1 plug.
STEP 3
STEP 4
Radio Receiver
+
Unplug the J1 socket and remove the old terminal block. Mount surge suppressor in same place as old terminal block.
STEP 5
Connect green ground wire to the chassis. DO NOT USE METAL PLATE
STEP 6
Plug the surge suppressor's J1 plug into control board and reconnect battery. Plug transformer back in.
Test all the accessories in combination with the gate operator to corroborate proper installation and functionality. For Technical Support: 1-800-528-2806
®
TM
J2
1. 5A - 250V
Robo Swing R900TM Surge Suppressor Step-by-Step Installation
STEP 1 STEP 2
Unplug the power transformer, battery connection and all accessory wires from terminal block.
1. 5A - 250V
Disconnect power transformer wires from J1 plug.
STEP 3
STEP 4
Unplug the J1 socket and remove the old terminal block.
STEP 5
Carefully break off the 2 studs that held the old terminal block. DO NOT use hammer!
STEP 6
Remove the two lower screws holding electronic box to chassis and mount the surge suppressor with plate in the electronic box with the two screws. Make Sure Green Ground Wire Makes
Good Contact With Chassis.
Plug the surge suppressor's J1 plug into control board and reconnect battery.
STEP 7
Test all the accessories in combination with the gate operator to corroborate proper installation and functionality. For Technical Support: 1-800-528-2806
Reconnect all accessory and power wires to surge suppressor module. [. . . ] All Rights Reserved
TM 845 Larch Avenue Elmhurst, Illinois 60126 www. chamberlain. com [. . . ]