User manual LIFT-MASTER MIRACLE ONE
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LIFT-MASTER MIRACLE ONE. We hope that this LIFT-MASTER MIRACLE ONE user guide will be useful to you.
Manual abstract: user guide LIFT-MASTER MIRACLE ONE
Detailed instructions for use are in the User's Guide.
[. . . ] TABLE
OF
CONTENTS
Attention: This handbook is exclusively for qualified installation personnel, and assistance and/or maintenance
service. - The performances indicated in this handbook are valid only if a correct assembly has been carried out. UL Listings and Instructions Role of Specifiers and Designers Role of Dealers, Installers and Trained Gate System Technicians Role of End Users / Home Owners Swing Gate Systems Warnings and Precautions "Open to the Inside" Mounting Specifications "Open to the Outside" Mounting Specifications Step-by-Step Operator Mounting Instructions Removing the Control/Surge Suppressor Boards Mounting the Control Box Wiring 1 Operator to the Surge Suppressor Board Wiring 2 Operators (Master/Second) to the Surge Suppressor Board Choosing Gate Movement Direction Sensor Adjustment Adjustable Timer Earth Ground Rod Installation Connecting Power Supply Wiring Additional Inputs Single Operator Loop Size and Placement Master / Second Loop Size and Placement Loop Installation and Number of Wire Turns Loop Detector Wiring Photocell Installation Single Control Board Description Master / Second Control Board Description Surge Suppressor Board Description Alarm / Maglock Control Board Connections UL Audio Alarm Burglar Alarm and Proximity Switch "Gate Opening Inside" Installation of Maglock / Solenoid Relay "Gate Opening Outside" Installation of Maglock / Solenoid Relay Close Delay Option (Master / Second Only) Emergency Key Release Troubleshooting Optional Solar Power Miracle 1 Accessories Miracle 1 Parts Illustration Miracle 1 Parts List / Maintenance Features and Specifications Quick Reference Surge Suppressor Wiring Diagram 2-5 6 6 7 7 8 9 10 11-14 15 15 16 17 18 18 19 19 20 21 22 23 24 25 26 27 28 29 30 31 31 32 33 34-35 36 37-39 40 41 42 43 45 46-47
Please DO NOT Touch me!. . . Unless you are an Authorized Service Technician!
© 1998-2004 by Chamberlain Professional Products
All rights reserved. [. . . ] After completing
all the electrical connections, continue to step 11 to complete the final adjustments on the operator.
13
PROCEDURE
FOR
INSTALLATION
Adjusting
the
Limit
Switches
Step 11: Adjust the travel distance of the gate with the limit switches. Position the outside limit switches of each armature to stop the gate in the "full open" and "full closed" positions. Re-tighten armature screws when gate positions are correct.
Outside Limit Switch Inside Limit Switch Limit Switch Armature Adjustment Screws
Inside Limit Switch Outside Limit Switch Adjustment Screws
Limit Switch Armature
Step 12: Reinstall the operator cover with the 4 screws to complete the installation. 14
REMOVING THE CONTROL / SURGE BOARDS
Unscrew the 4 Phillips head screws from the cover. Unplug all accessory wires from Surge Suppressor's removable terminals. 7 Remove three Phillips screws from surge suppressor board and remove board. 1 2 3 4
1
1
1
MAGLOCK
ALARM
SYSTEM ON
REVERSE SENSOR ALARM SENSOR
OPEN OUTSIDE
OPEN INSIDE
STOP BY POSITIVE STOP
REPLACE FUSE WHEN LED IS ON
NO
OFF
60
YES ON
3
POWER CHARGE OK BATTERY LOW
TIMER
CENTRAL
CONTROL
6
®
ACCESS SYSTEMS INC
RADIO CENTER STRIKE SAFETY REC LOOP OPEN LOOP
MIRACLE SURGE PROTECTION
®
MIRACLE SURGE PROTECTION
®
LAKE FOREST, CALIFORNIA
LAKE FOREST, CALIFORNIA
www. eliteaccess. com
www. eliteaccess. com
REV A
2
SLAVE ONLY
UL SENSOR BURGLAR ALARM INPUT +24 VOLT GROUND CENTER LOOP MOTOR BLACK WHITE BRAKE BROWN RED LIMITS GREEN BLUE LIMITS GREEN BLUE SAFETY LOOP BROWN RADIO EXIT LOOP 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
2
+24 VAC INPUT
8
REV A
BLACK
WHITE
RED
3
BURGLAR ALARM INPUT
SINGLE OR MASTER ONLY
MOTOR BRAKE
+24 VOLT
GROUND
CENTER LOOP
MOTOR BLACK WHITE
BRAKE BROWN RED
LIMITS GREEN BLUE
MOTOR BLACK WHITE
BRAKE BROWN RED
LIMITS GREEN BLUE
UL SENSOR
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
1
2
3
26
27
4 4 MOUNTING
Caution:
THE
CONTROL
BOX
Do Not make new mounting holes, or enlarge existing holes in control box. Use the four mounting holes provided.
Remove the four nuts and remove battery rack. Reverse this process to reinstall.
Mount control box with four screws and washers (recommend #10 thru 1/4-20 Bolts or Screws) Do Not over tighten.
15
+24 VAC INPUT
SAFETY LOOP
RADIO
EXIT LOOP
5
SINGLE OR MASTER ONLY
SLAVE ONLY
7
27
WIRING
MIRACLE SURGE PROTECTION
®
1
OPERATOR
TO
BOARD
LAKE FOREST, CALIFORNIA
www. eliteaccess. com
Caution: Do Not over-bend the cord from the operator. Doing this will cause the wires to eventually break.
REV A
Caution: Do Not use wire less than 16 gauge up to 200 Ft.
Removable Terminal Connector
+24 VOLT GROUND
Wire
SINGLE OR MASTER ONLY
MOTOR BLACK WHITE BRAKE BROWN RED LIMITS GREEN BLUE BLACK
SECOND ONLY
BURGLAR ALARM INPUT CENTER LOOP MOTOR WHITE BRAKE BROWN RED LIMITS GREEN BLUE UL SENSOR +24 VAC INPUT 26 27 SAFETY LOOP RADIO
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16 17 18 19 20 21 22 23 Caution: Make sure BARE WIRE 24
EXIT LOOP
25
Removable Terminal Connector
makes good contact inside removable terminal connectors. DO NOT let wire insulation interfere with connection.
1 Black
2 White
3 Red
4 Brown
5 Blue
6 Green
Important:
Install the Conduit (supplied) to secure the wire to the Miracle 1 Control Board Box. If the conduit can not be used, Install a dedicated water tight conduit for 6 wires. More than 20 ft run, you MUST use Shielded Wire for the blue and green lines. Shield must be grounded.
MIRACLE SURGE PROTECTION
®
LAKE FOREST, CALIFORNIA
www. eliteaccess. com
8
REV A
SINGLE OR MASTER ONLY
MOTOR BLACK WHITE BRAKE BROWN RED LIMITS GREEN BLUE BLACK
SECOND ONLY
BURGLAR ALARM INPUT +24 VOLT GROUND CENTER LOOP MOTOR WHITE BRAKE BROWN RED LIMITS GREEN BLUE UL SENSOR +24 VAC INPUT 26 27 SAFETY LOOP STRIKE INPUT RADIO 24
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
25
Supplied Conduit
16
WIRING
2
OPERATORS
MASTER
/
SECOND
MIRACLE SURGE PROTECTION
®
LAKE FOREST, CALIFORNIA
www. eliteaccess. com
6 Wires, 16 AWG from operator in dedicated water tight conduit. Operator 2 (Second)
Water Tight J-Box Kit Elite # K55-09853
REV A
Operator 1 (Master)
Caution: Do Not use wire less than 16 gauge
up to 200 Ft.
SINGLE OR MASTER ONLY
MOTOR BLACK WHITE BRAKE BROWN RED LIMITS GREEN BLUE BLACK
SECOND ONLY
BURGLAR ALARM INPUT +24 VOLT GROUND CENTER LOOP MOTOR WHITE BRAKE BROWN RED LIMITS GREEN BLUE UL SENSOR +24 VAC INPUT 26 27 SAFETY LOOP RADIO 24
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
www. eliteaccess. com
®
20
21
EXIT LOOP 22
23
25
MIRACLE SURGE PROTECTION
LAKE FOREST, CALIFORNIA
Removable Terminal Connectors
REV A
SINGLE OR MASTER ONLY
MOTOR BLACK WHITE BRAKE BROWN RED LIMITS GREEN BLUE BLACK
SECOND ONLY
BURGLAR ALARM INPUT +24 VOLT GROUND MOTOR WHITE BRAKE BROWN RED LIMITS GREEN BLUE UL SENSOR CENTER LOOP +24 VAC INPUT 26 27 SAFETY LOOP STRIKE INPUT RADIO 24
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
25
1 Black
2 White
3 Red
4 Brown
5 Blue
6 Green
7 Black
8 White
9 10 11 12 Brown Shield Green Blue Red
Supplied Conduit
Important:
Master
Removable Terminal Connector
Second
Install the Conduit (supplied) to secure the Master Operator to the Control Board Box. More than 20 ft run, you MUST use Shielded Wire for the blue and green lines. Shield must be grounded.
Wire
Supplied Water Tight Conduit (Not Supplied)
Caution: Make sure BARE WIRE makes good contact inside removable terminal connectors. DO NOT let wire insulation interfere with connection.
17
CHOOSING
GATE
MOVEMENT
DIRECTION
Switch the "Open Inside / Open Outside" switch on the control board to the corresponding position for the proper direction.
8
The gate opens inward.
The gate opens outward.
SENSOR
ADJUSTMENT
Caution: The sensors must be adjusted while the gate is in the opening or closing cycle.
Adjusted by Qualified Service Personnel
Minimum Sensitivity
8
Maximum Sensitivity Set the sensor adjustment so when the gate hits any object while opening, it will stop and when the gate hits any object while closing, it will reverse.
Option
Stop by Positive - Stop
This option is to be turned to "yes" if the gate will use positive stops at the close position.
Note: If you activate the operator and the gate stops in the middle of the
driveway, the sensor is set too sensitive.
Important: It is necessary to still adjust your limit switch at the close position.
The controller will look for the limit close first and then it will look for the positive stop.
18
ADJUSTABLE TIMER
Timer On
Set Timer 1 to 60 Seconds
Timer Off
If secondary safety sensor devices are not used when timer is ON, gate will hit vehicle obstructing gate path.
EARTH GROUND ROD INSTALLATION
Proper grounding gives an electrical charge, such as from an electrical static discharge or a near lightning strike, a path from which to dissipate its energy safely into the earth. Without this path, the intense energy generated by lightning could be directed towards the Elite gate operator. Although nothing can absorb the tremendous power of a direct lightning strike, proper grounding can protect the gate operator in most cases. The earth ground rod must be located within 3 feet from the gate operator. If you should cut the ground wire too short, break it, or destroy its integrity, replace it with a single wire length.
Connect ground wire to green wire from surge suppressor board
Use 12 gauge ground wire
Before digging more than 18" deep, contact local underground utility locating companies
Avoid damaging gas, power, or other underground utility lines.
Chamberlain Professional Products is not responsible for improper installation or failure to comply with all necessary local building codes.
19
REV A
CONNECTING
POWER
SUPPLY
Connect Elite's plug-in transformer (24 VAC Included) to Surge Suppressor board, terminals #26 and #27. [. . . ] The radio receiver has malfunctioned in the "ON" position.
Control Board LED
The Gate Will Not Open!
Symptom: The radio receiver LED on the
control board remains "OFF" when using the remote control. Remote control code switches are different from radio receiver code switches. The radio receiver has malfunctioned in the "OFF" position.
CENTRAL
CONTROL
Possible Solutions:
Control Board LED
38
TROUBLESHOOTING
You will SEE the alarm LED "ON" when. . .
SYSTE ON
SE REVER R SENSO
For Toll Free Technical Support: 1-888-ELITE-10
M
ALARM R SENSO
Horizontal Gate Level line Vertical Gate Level line
Incorrect Installation
1 The gate is too heavy or the operator or gate is installed incorrectly.
2 A foreign object is on the gate frame while the gate is moving.
3 Gate hinges are too tight or broken and the gate is not moving freely.
4 The gate hits the driveway, curb or other, and gets stuck in an awkward position.
39
OPTIONAL
SOLAR
POWER
Elite offers a plug-in solar adapter and solar panel as an option for the Miracle 1. Elite's "SOLAR 3" solar panel provides solar power for the Miracle 1 single and double arm operators. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE LIFT-MASTER MIRACLE ONE
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LIFT-MASTER MIRACLE ONE will begin.