User manual LIFT-MASTER LM90-RR

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LIFT-MASTER LM90-RR. We hope that this LIFT-MASTER LM90-RR user guide will be useful to you.


LIFT-MASTER LM90-RR : Download the complete user guide (240 Ko)

Manual abstract: user guide LIFT-MASTER LM90-RR

Detailed instructions for use are in the User's Guide.

[. . . ] The Release Device is available in fixed and adjustable time delay options, Models RR and RRD. CAUTION: Review all installation instructions, procedures, cautions and warnings contained within this manual prior to installing and/or servicing this product. As with all releasing device systems, maximum fire protection is provided when installed in accordance with factory specifications and used with fuse link systems. TEST SYSTEM REGULARLY TO ASSURE PROPER OPERATION. Installation and testing to factory specifications shall be performed by factory authorized personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters Laboratories (UL), National Electrical Code (NEC), local, state, county, district and/or other applicable building and fire standards, guidelines, regulations and codes including, but not limited to, all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). INSTALLATION INSTRUCTIONS - To be performed by factory authorized personnel only. The following installation procedures must be followed to assure performance of the release device to factory standards. [. . . ] Use Model RRD if the installation is stand alone and a delay is required 1. Verify voltage rating of release device to power source being utilized. Connect power source inputs (through normally closed initiating device) to red (+) and black (-) wires. Daisy chain configuration provides time delay feature from master unit (Model B2 Master). Independent delays are set inside master unit there is a 10 second alarm (factory set) and battery support for power loss. Use only the LM90-RR in daisy chain configuration to avoid doubling the time delay. 2) Connect red (+) wire from LM90-RR-12 to wiring from TB1-15 and black wire to wiring from TB2-1. Review Figure 3A for additional wiring required inside of master unit. DO NOT LEAVE COVER OPEN AFTER CONNECTIONS ARE MADE! 2 LM90-RR LM90-RRD Horizontal pull FIGURE 1 FIGURES 1 AND 1A DEPICT MOUNTING OPTIONS FOR REMOTE RELEASE AND ARE NOT PROVIDED AS GUIDELINES FOR THE INSTALLATION OF THE DOOR OR ASSOCIATED HARDWARE. SEE DOOR MANUFACTURERS RECOMMENDATIONS AND NFPA 80 FOR USE OF THIS PRODUCT, FUSIBLE LINKS AND ASSOCIATED HARDWARE USED WITH SPECIFIC DOOR. ACTUAL CONFIGURATION MAY VARY SIGNIFICANTLY FROM ILLUSTRATIONS PROVIDED. FIGURE 1A LM90-RR LM90-RRD Vertical pull 3 LM90-RR INSIDE VIEW (Cover removed) FIGURE 2 Reset Knob Power LED Manual Test Button FIGURE 3 - ELECTRICAL WIRING (+) (2) Initiating Device (Smoke detector, etc. ) (1) Input power (-) LM90-RR (REMOTE RELEASE) LM90-RRD (DELAY OPTION) (+) (-) Chassis ground RED BLACK (1) Verify input voltage to model being used. (2) See NFPA 80 and NFPA 72 for proper placement. Installation of all wiring and related connecting hardware must be performed in accordance with the latest NFPA, UL, and NEC standards and codes. In addition, all installations subject to Canadian standards shall be performed in accordance with the Canadian Electrical Code, Part I, with respect to wiring material type, wiring gauge related to power capacity requirements and circuit length and wiring methods. 4 FIGURE 3A - ELECTRICAL WIRING : TIME DELAY DAISY CHAIN CONFIGURATION SMOKE DETECTOR OR ALARM PANEL NORMALLY CLOSED DRY CONTACT LOOP (5) LM90-B2 Master 1 TB-1 1 2 3 (2) (+) (-) RED BLACK LM90-RR #3 (+) (-) 14 15 18 1 2 TB-2 (-) (4) (+) (-) RED BLACK LM90-RR #2 RED BLACK LM90-RR #1 (1) 18 (3) (+) Refer to page 1, Section C for wiring descriptions. Wiring of the remote releases in a Daisy Chain configuration to a master unit provides time delayed release with simultaneous closure on all doors. A maximum of three (3) units may be daisy chained from the master unit. See installation manual of master unit for additional information. Installation of all wiring and related connecting hardware must be performed in accordance with the latest NFPA, UL, and NEC standards and codes. In addition, all installations subject to Canadian standards shall be performed in accordance with the Canadian Electrical Code, Part I, with respect to wiring material type, wiring gauge related to power capacity requirements and circuit length and wiring methods. 5 "LM90" SERIES RELEASE DEVICE ELECTRICALAND MECHANICAL CHARACTERISTICS ELECTRICALRATINGS MODEL (D- delay option) VOLTAGE LM90-RR-12 / LM90-RRD-12 12VDC LM90-RR-24 / LM90-RRD-24 24VDC MECHANICAL- LOAD RATING Support and release: 40LB. 15. 0 28. 0 CURRENT . 050A . 050A DIMENSIONS 6" x 4 " x 3 1/8" (H x W x D) SECTION D. TESTING SHALL BE WITNESSED FOR PROPER OPERATION. Testing does not affect normal operation of alarm system when connected to release device. Testing and normal operation can only be accomplished with power applied to unit. When power is applied to unit under test the Power LED (red) will be lit on the bottom of the release device. CLEAR FIRE DOOR OPENING AND PROHIBIT ALL TRAFFIC THROUGH DOOR OPENING DURING TESTING OF SYSTEM! Door must be in open position with power applied to unit and/or master unit on Daisy chain configurations. [. . . ] Troubleshooting shall be performed by factory authorized personnel only. Service and/or installation by unauthorized personnel shall void warranty. When using Daisy Chain configuration, call tech support before troubleshooting. If technical support is required, unit serial number (found on front of manual and inside unit), as well as distributor who supplied unit must be provided. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LIFT-MASTER LM90-RR




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LIFT-MASTER LM90-RR will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.