User manual LIFT-MASTER LA400
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LIFT-MASTER LA400. We hope that this LIFT-MASTER LA400 user guide will be useful to you.
Manual abstract: user guide LIFT-MASTER LA400
Detailed instructions for use are in the User's Guide.
[. . . ] OWNER'S
MANUAL
MODEL LA400
MEDIUM DUTY SWING GATE OPERATOR
2 YEAR WARRANTY
Serial # Primary Arm Serial # Secondary Arm Serial # Box Installation Date
TABLE OF CONTENTS TABLE OF CONTENTS
OPERATOR SPECIFICATIONS
Tools Needed for Installation . . 4
WARNING
Mechanical
WARNING
OPERATOR WARNINGS CAUTION
Safety Installation Information . . 7
CAUTION WARNING WARNING Electrical WARNING CAUTION
When you see these Safety Symbols and Signal Words on the following pages, they will alert you to the possibility of serious injury or death if you do not comply with the warnings that accompany them. When you see this Signal Word on the following pages, it will alert you to the possibility of damage to your gate and/or the gate operator if you do not comply with the cautionary statements that accompany it. [. . . ] The transformer can be plugged into a receptacle external to the control box. Alternatively, you can connect 120VAC directly to the box, and plug the transformer to the receptacle inside the control box. 120VAC POWER WIRE (STRANDED COPPER WIRE) Wire Gauge 16 10 Length 100' (30 m) 1000' (305 m)
CONNECT ARM TO CONTROL BOX
Connect the wires from the operator to connector P17 for the Gate 1 operator as shown in the wiring diagram on page 26. If connecting a second arm, follow the same instructions on connector P16. 24VAC TRANSFORMER (STRANDED COPPER WIRE) Wire Gauge 14 12 Length 500' (152 m) 1000' (305 m)
Motor Wiring Power Wiring Control Wiring
EARTH GROUND ROD INSTALLATION (OPTIONAL)
When installing the optional earth ground rod, disconnect and remove the green/yellow ground wire connected to the screw terminal of the printed circuit board. For proper operation, Control Box the earth ground rod should not be connected to the ground of your power wiring. Ensure the power wiring ground connection remains securely connected to the Earth Ground 12 gauge green screw on the outlet Installation wire plate. Attach earth ground rod wire to the screw terminal of the printed circuit board marked . 13
WARNING CAUTION
To AVOID damaging gas, power, or other underground utility lines, contact underground utility locating companies BEFORE digging more than 18" (46 cm) deep.
WARNING
CONTROL WIRING
P2 P1 R223
CAUTION
J19 K6 Ø14GPØ89ØE Ø14LGØ89ØE Ø14SKØ89ØE J1
CLOSE EDGE
R2Ø7 Z2Ø R227
To reduce the risk of FIRE or INJURY to persons, use ONLY Chamberlain part #K74-30762 for replacement batteries.
ALARM
NO C
MAGLOCK
K5
NO C NC
Z1 10A 32V
OPEN EDGE/ PHOTO
L1 J18 U4 R224 Z22 R92 Z9
1
R2
O N
S8
R1
LEARN XMITTER
GATE 1
2
F3
OFF OFF SINGLE NO NO
ON ON DUAL NC NC
SAVE MAGLOCK MODE EDGE PHOTO
12345 S1
OPEN PHOTO
R91 R94 Z8
BRN GRN WHT YEL BLU RED
Z12 K1 Q9 D1Ø K2
DIAGNOSTIC
R93
CLOSE PHOTO
GATE 1
SET OPEN LIMIT
SET CLOSE LIMIT
LEARN LIMITS
24V
SWITCHED ACCESSORY POWER CONTROL INPUTS OPEN SINGLE BUTTON
ACCESSORY POWER
R9Ø
GATE 2
TIMER RUNNING
COM OVLD OVLD
24V
R1Ø1
FORCE
BIPART DELAY
TIMER TO SINGLE BUTTON CLOSE
BRN GRN WHT YEL BLU RED
GATE 2
10A 32V
R1ØØ F4
ACCESSORY OVLD
K4 F5 D21 K3 D8 C12
RESET STOP
MIN
MAX
OFF
MAX
OFF
MAX
COM COM
POWER
BATT 2 B ATT 1
LOOP INPUTS
R35 D9 D27 Z3 Z4 F7 C13 U3 C11 C4
Q22
D22
SHADOW INTERRUPT CHGR OVLD
F6 F2
D15 R4 C2 R196
COM
24 VAC/ SOLAR INPUT J4
F1 2ØA 32V
MOV2 MOV1 C64 JMPR2 U2 DB1
R9 D1 JMPR1 D6
D4
D2
FUSE OPEN
BATT 2
BATT 1
BATTERY The main source of power for the operator is the batteries. The batteries can be charged in circuit by using a charging transformer or solar panels.
24 VAC/ SOLAR INPUT J4
MOV2
USE DEDICATED CIRCUIT
CHARGING The 24VAC input can accept a charging transformer (26VAC, 29VA).
OR
SOLAR PANELS Optional solar panels may be used to charge the batteries. Solar Panels (LA400-SPK) must be a minimum of 27. 4V, 9W output.
14
BASIC CONTROL BOARD SETUP
20 19 17 26 1
P2 P1 R223
J19 K6
ALARM
Ø14GPØ89ØE Ø14LGØ89ØE Ø14SKØ89ØE J1
CLOSE EDGE
R2Ø7 Z2Ø R227
14
MAGLOCK
NO C
K5
2
OPEN EDGE/ PHOTO
13
Z1
NO C NC 1
R2
L1 J18 U4 R224 Z22 R92 Z9
3
OPEN PHOTO
O N
S8
R1 10A 32V
LEARN XMITTER
18 12
GATE 1
2
F3
OFF OFF SINGLE NO NO
ON ON DUAL NC NC
SAVE MAGLOCK MODE EDGE PHOTO
12345 S1
R91 R94 Z8
BRN GRN WHT YEL BLU RED
Z12 K1 Q9 D1Ø K2
4
CLOSE PHOTO
DIAGNOSTIC
R93
GATE 1
5
24V
SWITCHED ACCESSORY POWER CONTROL INPUTS OPEN
SET OPEN LIMIT
SET CLOSE LIMIT
LEARN LIMITS
6* 22 7
ACCESSORY POWER
R9Ø
GATE 2
TIMER RUNNING
COM OVLD OVLD
11* 10
GATE 2
24V
R1Ø1
FORCE
BIPART DELAY
TIMER TO SINGLE BUTTON CLOSE
BRN GRN WHT YEL BLU RED
10A 32V
R1ØØ F4
SINGLE BUTTON ACCESSORY OVLD RESET STOP
K4 F5 D21 K3 D8
MIN
MAX
OFF
MAX
OFF
MAX
COM COM
POWER
R35 D9 C12 D27 Z3 Z4 F7 C13 U3 C11 C4
LOOP INPUTS SHADOW INTERRUPT CHGR OVLD
Q22
D22
8
COM
D15 R4 C2 R196 F6
21
24 VAC/ SOLAR INPUT J4
F2
F1 20A 32V
MOV2 MOV1 C64 JMPR2 U2 DB1
R9 D1 JMPR1 D6
D4
D2
FUSE OPEN
BATT 2
BATT 1
9
23
24
25
16 15
ITEM 1 2 3 4 5 6 7 8 9 10 11 12 13
DESCRIPTION Connector P1 Connector P6 Connector P8 Connector P7 Connector P9 Connector P12 Connector P10 Connector P11 Connector P5 Connector P16 Connector P13 Connector P17 Connector P14
FUNCTION Antenna Input Close Edge Open Edge/Photo Open Photo Close Photo Switched Accessory Power* Control Inputs Loop Inputs 24Vac/Solar Input Gate 2 Accessory Power* Gate 1 Maglock/Solenoid
ITEM 14 15 16 17 18 19 20 21 22 23 24 25 26
DESCRIPTION Connector P15 Connector Connector Dip Switch Pushbutton Pushbuttons Pushbutton Pushbuttons Pushbutton Potentiometer Potentiometer Potentiometer Connector
FUNCTION Alarm Battery 1 Battery 2 S1 Learn Xmitter - Program Remote Gate 1 - Jog Learn Limit Learn Limits Gate 2 - Jog Learn Limit Single Button Force Bi-Part Delay Timer to Close Receiver
*Maximum 300 mA combined output 15
SET DIP SWITCH FOR GATE TYPE
1. The Save switch must be set to the OFF position prior to setting or changing the switches. NOTE: When setting switches S2-5, the Save switch must be in the OFF position prior to setting or changing switches for the change to be saved.
O N
P2 P1
R223
J19 K6
ALARM
J1
Ø14GPØ89ØE Ø14LGØ89ØE Ø14SKØ89ØE
CLOSE EDGE
R2Ø7 Z2Ø R227
NO C
MAGLOCK
K5
OFF OFF SINGLE NO NO
Z9
ON ON DUAL NC NC
SAVE MAGLOCK MODE EDGE PHOTO
12345
NO C NC
Z1 10A 32V
OPEN EDGE/ PHOTO
L1 J18 U4 R224 Z22 R92
S1
1
R2
O N
S8
R1
LEARN XMITTER
GATE 1
2
F3
OFF OFF SINGLE NO NO
ON ON DUAL NC NC
SAVE MAGLOCK MODE EDGE PHOTO
12345 S1
OPEN PHOTO
R91 R94 Z8
BRN GRN WHT YEL BLU RED
Z12 K1 Q9 D1Ø K2
DIAGNOSTIC
R93
CLOSE PHOTO
GATE 1
SET OPEN LIMIT
SET CLOSE LIMIT
LEARN LIMITS
24V
SWITCHED ACCESSORY POWER CONTROL INPUTS OPEN SINGLE BUTTON
ACCESSORY POWER
R9Ø
GATE 2
TIMER RUNNING
COM OVLD OVLD SINGLE BUTTON
O N
24V
R1Ø1
FORCE
BIPART DELAY
TIMER TO CLOSE
BRN GRN WHT YEL BLU RED
GATE 2
10A 32V
R1ØØ F4
ACCESSORY OVLD
K4 F5 D21 K3 D8 C12
RESET STOP
MIN
MAX
OFF
MAX
OFF
MAX
COM COM
POWER
R35 D9 D27 Z3 Z4 F7 C13 U3 C11 C4
LOOP INPUTS SHADOW INTERRUPT CHGR OVLD
Q22
D22
OFF OFF SINGLE NO NO
ON ON DUAL NC NC
12345
D15 R4 C2 R196 F6
COM
24 VAC/ SOLAR INPUT J4
F2
F1 20A 32V
MOV2 MOV1 C64 JMPR2 U2 DB1
R9 D1 JMPR1 D6
D4
D2
FUSE OPEN
BATT 2
BATT 1
O N
OFF OFF SINGLE NO NO
ON ON DUAL NC NC
12345
16
PROGRAMMING REMOTE
1. Press remote button, the LED will flash, alarm output will activate twice. Repeat steps 1 and 2 until all remotes are programmed (50 remotes maximum). NOTE: For highest level of security, we recommend the Security® line of products.
COMPATIBLE REMOTES - 315MHz
PassportTM Remote CPT13 CPT23 CPT33 Security® Keyless Entry 376LM Security® Remotes 370LM 371LM 372LM 373LM 374LM
R1
LEARN XMITTER
2
J19 K6
P2 P1
ALARM
J1
Ø14GPØ89ØE Ø14LGØ89ØE Ø14SKØ89ØE
NO C
MAGLOCK
K5
NO C NC
Z1 10A 32V
L1
1
R2
O N
S8
R1
LEARN XMITTER
GATE 1
2
F3
OFF OFF SINGLE NO NO
ON ON DUAL NC NC
SAVE MAGLOCK MODE EDGE PHOTO
12345 S1
BRN GRN WHT YEL
D1Ø K2
DIAGNOSTIC
LiftM
ast er
BLU RED
Z12 K1 Q9
GATE 1
SET OPEN LIMIT
SET CLOSE LIMIT
LEARN LIMITS
NOTICE: To comply with FCC and or Industry Canada (IC) rules, adjustment or modifications of this receiver and/or transmitter are prohibited, except for changing the code setting or replacing the battery. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
WIRE STOP BUTTON (OPTIONAL)
A jumper wire is factory installed between the stop and common input. Stop (N/C) - Stop only (does not reset alarm).
P2 P1 R223
J19 K6
ALARM
J1
Ø14GPØ89ØE Ø14LGØ89ØE Ø14SKØ89ØE
CLOSE EDGE
R2Ø7 Z2Ø R227
NO C
MAGLOCK
K5
NO C NC
Z1 10A 32V
OPEN EDGE/ PHOTO
L1 J18 U4 R224 Z22 R92 Z9
1
R2
O N
S8
R1
LEARN XMITTER
GATE 1
2
F3
OFF OFF SINGLE NO NO
ON ON DUAL NC NC
SAVE MAGLOCK MODE EDGE PHOTO
12345 S1
OPEN PHOTO
R91 R94 Z8
BRN GRN WHT YEL BLU RED
Z12 K1 Q9 D1Ø K2
DIAGNOSTIC
R93
CLOSE PHOTO
CONTROL INPUTS OPEN
GATE 1
SET OPEN LIMIT
SET CLOSE LIMIT
LEARN LIMITS
24V
SWITCHED ACCESSORY POWER CONTROL INPUTS OPEN SINGLE BUTTON
ACCESSORY POWER
R9Ø
GATE 2
TIMER RUNNING
SINGLE BUTTON RESET STOP
COM OVLD OVLD
24V
R1Ø1
FORCE
BIPART DELAY
TIMER TO SINGLE BUTTON CLOSE
BRN GRN WHT YEL BLU RED
GATE 2
10A 32V
R1ØØ F4
ACCESSORY OVLD
K4 F5 D21 K3 D8 C12
RESET STOP
MIN
MAX
OFF
MAX
OFF
MAX
COM COM
POWER
R35 D9 D27 Z3 Z4 F7 C13 U3 C11 C4
COM
LOOP INPUTS
Q22
D22
SHADOW INTERRUPT CHGR OVLD
F6 F2
COM
POWER
D15 R4 C2 R196
COM
24 VAC/ SOLAR INPUT J4
F1 20A 32V
MOV2 MOV1 C64 JMPR2 U2 DB1
R9 D1 JMPR1 D6
D4
D2
FUSE OPEN
BATT 2
BATT 1
17
OPTIONAL CONTROL DEVICES
SBC (Single Button Control) Input (N/O) This input will command the gate to OPEN / STOP / CLOSE / STOP in sequence. Reset Control Input (N/O) The control box has a factory installed internal reset button. These terminals are intended for use with a single reset button that is installed within line of sight of the gate. Open Input and Exit Loop These terminals are intended for use as a general open control. Accessories such as telephone entry systems, radio receivers (open only applications), exit loop detectors, keypads and 7-day timers may be wired to this input.
PR
ESE NC RE E LAY 2
Sa
EXIT LOOP
5 62
ras
ota
X
62
SE NS
FRE EQQ
5X
IN DE MA A US
OPEN COMMON
AND/OR
CONTROL INPUTS OPEN SINGLE BUTTON RESET STOP
SINGLE BUTTON COMMON
COM
COM
POWER
AND/OR
COMMON RESET
P2 P1 R223
J19 K6
ALARM
J1
Ø14GPØ89ØE Ø14LGØ89ØE Ø14SKØ89ØE
CLOSE EDGE
R2Ø7 Z2Ø R227
NO C
MAGLOCK
K5
NO C NC
Z1 10A 32V
OPEN EDGE/ PHOTO
L1 J18 U4 R224 Z22 R92 Z9
1
R2
O N
S8
R1
LEARN XMITTER
GATE 1
2
F3
OFF OFF SINGLE NO NO
ON ON DUAL NC NC
SAVE MAGLOCK MODE EDGE PHOTO
12345 S1
OPEN PHOTO
R91 R94 Z8
BRN GRN WHT YEL BLU RED
Z12 K1 Q9 D1Ø K2
DIAGNOSTIC
R93
CLOSE PHOTO
GATE 1
SET OPEN LIMIT
SET CLOSE LIMIT
LEARN LIMITS
24V
SWITCHED ACCESSORY POWER CONTROL INPUTS OPEN SINGLE BUTTON
ACCESSORY POWER
R9Ø
GATE 2
TIMER RUNNING
COM OVLD OVLD
24V
R1Ø1
FORCE
BIPART DELAY
TIMER TO SINGLE BUTTON CLOSE
BRN GRN WHT YEL BLU RED
GATE 2
10A 32V
R1ØØ F4
ACCESSORY OVLD
K4 F5 D21 K3 D8 C12
RESET STOP
MIN
MAX
OFF
MAX
OFF
MAX
COM COM
POWER
R35 D9 D27 Z3 Z4 F7 C13 U3 C11 C4
LOOP INPUTS SHADOW INTERRUPT CHGR OVLD
Q22
D22
D15 R4 C2 R196 F6
COM
24 VAC/ SOLAR INPUT J4
F2
F1 20A 32V
MOV2 MOV1 C64 JMPR2 U2 DB1
R9 D1 JMPR1 D6
D4
D2
FUSE OPEN
BATT 2
BATT 1
18
LOOP INPUTS (P11) Shadow Loop Input Terminal and Common This input protects cars by preventing the gate from moving off of the open or close limit when the shadow loop input is active. [. . . ] Check the gate area to make sure all obstructions are removed.
MAGLOCK DOES NOT WORK Maglock does not hold gates locked
Check connections between the Maglock, its power supply, and the control board to make sure they are secure. Replace the control board.
DIAGNOSTIC CODES
# OF BLINKS
1 2 3 4 5 6 7 8 9 10
MEANING
No Stop Switch Connected Gate 1 Arm Disengaged Gate 2 Arm Disengaged Both Gate Arms Disengaged RPM Reversal Force Reversal Processor Reset ROM Check Failed RAM Check Failed EEPROM Check Failed
28
REPAIR PARTS
Refer to the parts lists below for replacement parts available for your operator. If optional modifications and/or accessories are included with your operator, certain components may be added or removed from these lists. CONTROL BOX LA400-CONT
ITEM 1 2 3 4 5 6 7 8 Not Shown PART # K001A6039 K75-15480 K75-30764 K23-19380 K74-19499 K74-30762 K74-30763 K76-19446 K74-30941 DESCRIPTION Control Board Control Box & Cover with Gasket Control Board Bracket Reset Switch Antenna Battery Transformer Alarm ATC Fuse Kit Includes 20 Amp (1), 15 Amp (2) QTY 1 1 1 1 1 2 1 1
8
2
7
3
4 1
6
5
29
REPAIR PARTS
ACTUATOR ARM KITS
ITEM 1 2 3 4 Not Shown PART # 41ASWG-442SA 41ASWG-438SA 41ASWG-0014SA 41ASWG-454 41ASWG-0119 DESCRIPTION Release Lever Motor with Limit Switch Harness Rear Connector Cable 24V with Connector Release Key QTY 1 1 1 1 1
2
1
3
4
30
O P E R AT O R N O T E S
31
WARRANTY POLICY AND SERVICE
LIFTMASTER® TWO YEAR LIMITED WARRANTY
The Chamberlain Group, Inc. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE LIFT-MASTER LA400
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LIFT-MASTER LA400 will begin.