User manual LIFT-MASTER HL410
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LIFT-MASTER HL410. We hope that this LIFT-MASTER HL410 user guide will be useful to you.
Manual abstract: user guide LIFT-MASTER HL410
Detailed instructions for use are in the User's Guide.
[. . . ] Strong winds will greatly affect the efficiency of this operator on these types of gates. IMPORTANT NOTE The gate must be level and operate smoothly and freely. If it does not, damage to the operator may result and the life expectancy will be greatly reduced.
Doc 01-20230 Rev B
6
Safety Information
Safety Information
Automatic gate operators provide convenience and security to their users. However, because these machines can produce high levels of force, it is important that all installers and users be aware oft he potential hazards associated with improperly installed or adjusted units. [. . . ] The operator must be level.
2
The two brackets should be welded to the gate and the post as shown. They can be welded directly or modified to suit your particular application.
FOR MODEL HL410-21
Dimension A 5" to 5-1/2" 4-1/2"to 5" 4"to 4-1/2" 3-1/2"to 4" Gate Opening 90° 100° 110° 120°
Do not weld brackets with operator attached. Avoid nicks.
MODEL HL410-21
Front Mounting Bracket (shortest) Hinge Point 10. 60 A 5"
3" to 3 1/2"
MODEL HL410L-21 - 90° OPENING
Hinge Point
32 1/2"
Open
4. 68 47. 81
3. 90
Rear Mounting Bracket (longest) Both Brackets In Line
Gate shown in the Left-Hand Closed Position
01-20230F5
Figure 3 Doc 01-20230 Rev B
Installation Step 3:
11
Optional Mounting
OUTWARD SWING
WARNING
Do not install outward swing gates in applications where gates will swing into public area. Use outward swing gates only in applications where the gate will open into secure area and where the person operating the gate has control of traffic in the path of the gate. Do not use the "Open Only" mode of the controller for an outward swing gate installation. Gate stops must be used at both the full open and close positions (see Step 1). The difference being that the rear mounting point is 5" to the right of the hinge point instead of 5" to the left as shown in Step 2 (distance between mounting points is 27-1/2" instead of 371/2"). The piston rod should be fully retracted when the gate is in the closed position. The unit should be mounted with the gate in the closed position (see Step 4). Follow wiring for outward swing.
LARGE PILLARS OR WALLS
If the dimension from the centerline of the gate to the outer edge of the pillar or wall is 3-3/4" or less, you can notch out part of the pillar or wall (see Example A Figure 4) as shown. If this dimension is larger than 3-3/4", then it will be necessary to notch out larger portion (see Example B Figure 4) large enough to house the unit. Contact a LiftMaster dealer if your application does not fit these guidelines.
OPTIONAL MOUNTING - NOTCH AS REQUIRED
01-20230F6
EXAMPLE A
EXAMPLE B
Figure 4 Doc 01-20230 Rev B
12
Installation Step 4: 1 2
Mounting
Manually open the gate and attach the unit to the two (2) mounting brackets (see Figure 5 below). Manually open and close the gate a few times to ensure the mounting brackets and gate stops are positioned properly with no interference (the unit is shipped in the disconnect position to allow for this). Mount the controller in a convenient location, within reach of the unit's 4 ft. Make sure the cord is not stretched taut (it should have a slight amount of slack during the full cycle). Refer to the electrical diagram attached to the inside of the controller door for accessory wiring. Please install all safety devices necessary to make this installation as safe as possible.
Control Wiring Terminal Strip
1 2 4 5 6 8 9 10 D1 D1 D2 D2
24 VAC.
OPEN/CLOSE If the gate is closed, when activated, it will open. If the unit is activated for open only, it must be used in conjunction with the Stop feature, or a hazardous and dangerous condition may be present. You will also need the optional automatic close timer.
Radio Control to Open / Close
STOP A device such as a reversing edge, loop detector, or photo beam can be used as a Stop device. It must have a normally closed contact.
Reversing Device Used as Stop
Reversing Device Will reverse both directions 4 5
Norm. open "only" Reversing Device
4 2 Normally Closed If used, remove jumper 2 to 4 Loop Detector to Open Only
6
9 10 5 4 RED BLK GREY GREY If used, leave jumper 6 to 7 in
8
Loop Detector to Reverse while closing
If used, remove jumper 6 to 7
IT IS RECOMMENDED THAT IF A OPEN ONLY IS USED, A STOP BE USED WITH IT . .
Open Only
Stop
45
GRN WHITE
7 8 9 10
1 2 3 7 8 9 10
1
PURP RED RED YEL ORG
2 4
If used, remove jumper 2 to 4
RED
14
9 10 D1 D1
RED
4
6 7 8 9 10 D2 D2
0 1 -2 0 2 3 8 F7
Slave Unit
Auto. [. . . ] In case of failure due to deficiencies in material or workmanship during the warranty period, the completer gate operator will be repaired or replaced at the manufacturer's option. Replacement parts are warranted for the remaining portion of the original warrant period. LiftMaster will pay freight on our return of repaired or replaced items in warranty. This warranty gives you specific rights, and you may also have other rights which vary form state to state.
Doc 01-20230 Rev B
20
Parts List
Parts List
Hatch Kit
MG49258
Mounting Pin Kit
MG49136
End Cap
MG49196
Disconnect Hex Key
MG5100812
Mounting Clip
MG5100816
Drive Unit
Rod Cover
MG5100813
Power Cord
MG24719
C-Clip Kit MG49136 Rear Mounting Bracket MG5100815 Front Mounting Bracket
MG5100814
Connector Kit
MG49133
Capacitor
MG3101962
Main Circuit Board
MG49070 or MG49110
Micro Circuit Board
MG49071 OR MG49111
Fuse Kit MG49135 Relay MG3101963 Fuse Kit MG49135 Circuit Bd. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE LIFT-MASTER HL410
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LIFT-MASTER HL410 will begin.