User manual LIFT-MASTER CPSII-N4
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LIFT-MASTER CPSII-N4. We hope that this LIFT-MASTER CPSII-N4 user guide will be useful to you.
Manual abstract: user guide LIFT-MASTER CPSII-N4
Detailed instructions for use are in the User's Guide.
[. . . ] CDO Protector System® OWNER'S MANUAL
Models: CPS-N4, CPSII-N4 and CPS-LN4
WARNING
This device is for use ONLY with LiftMaster Commercial Door Operators. Use on other than recommended equipment voids warranty, and may cause PROPERTY DAMAGE or SERIOUS PERSONAL INJURY. Have door in full open or closed position and disconnect power to the garage door opener BEFORE installing the CDO Commercial Protector System®.
WARNING WARNING
CAUTION
Installation procedures are the same for all door types.
--Left Side of Garage--
-- Right Side of Garage --
Safety Reversing Sensor
Invisible Light Beam Protection Area
Safety Reversing Sensor
Facing the door from inside the garage
Install the Commercial Protector System®
IMPORTANT INFORMATION ABOUT THE SAFETY REVERSING SENSOR
Be sure power to the opener is disconnected. [. . . ] For sensing above 6" (15 cm), a second set of eyes would be required.
Figure 1 Wall or Floor Mounting
Hex Mounting Nut for Sensor Lock Washer for Sensor
Floor or Wall Mount
For typical floor or wall mounting applications see Figure 1. If necessary, see Figure 2 for various assembly options to fit your application. NOTE: Putting track bolts in slots will prevent brackets from pivoting. To attach to concrete use concrete anchors (not provided).
1/4"-20 x 5/8" Track Bolts
Track Mount
To mount to door track use only one bracket per side (Figure 3).
1/4"-20 x 5/8" Track Bolts 1/4" Flat Washer 1/4" Lock Washer 1/4"-20 Hex Nut 1/4" x 1-1/2" Lag Screws
Figure 2 Assembly Variations
Assemble to either side Flip one bracket and assemble to either side
Figure 3 Door Track Mounting
1/4" Flat Washer 1/4" Lock Washer 1/4"-20 Hex Nut 1/4" Lock Washer 1/4"-20 Hex Nut Door 1/4" Drill Holes
1/2" Hole Spacing
2" Hole Spacing
1/4"-20 x 5/8" Track Bolts
To attach vertically to 2" x 4" wall stud and prevent wood from splitting, bracket may also be rotated with leg on top. Shown with leg on bottom.
CONDUIT CONNECTIONS
Use a liquid tight fitting (1/2" trade size) with sealing washer to connect to sensors. We recommend the use of a liquid tight junction box near each sensor to make the connection to the sensor leads. Use rigid or flexible liquid tight conduit (depending on local codes) from junction boxes to operator. copper wire for connection between the sensors and the operator.
Liquid Tight Junction Box Liquid Tight Conduit
WIRING CONNECTIONS
CPS-N4: See top of page 3 CPSII-N4: See middle of page 3 CPS-LN4: See page 4 and 5
See Wiring Connections
Sensor Beam 6" (15 cm) max. above floor
Liquid Tight Junction Box Invisible Light Beam Protection Area Sensor Beam 6" (15 cm) max. above floor
Figure 4
2
CPS-N4 Wiring Connections
Commercial Protector Interface 24V Common Sensor Brown Sensor Blue
CDO Sensing Edge Input
To Sending Eye (Emitter) and Receiving Eye (Receiver)
CPSII-N4 Wiring Connections for use with Solid State Logic Control Board
CPSII Option PCB
Terminals Green Lights
Insert PCB into any or four slots
IR Protector Only
A B C D E F G H I J
CDO Motherboard
IR Protector and 2-Wire Fail Safe Door Edge
IR Protector and 4-Wire Fail Safe Door Edge
A B C D E F G H I J
A B C D E F G H I J
NOTE: Logic 2 Board will have the same connection.
3
CPS-LN4 Wiring Connections for use with Solid State II (Logic Control Board Ver 2)
Blue
Brown
TO ACTIVATE SAFETY SENSOR EYES
ON
ON SET TIMER TO CLOSE 1 2 3 4
1. Run the door through one full close-open-close cycle to "Learn" the sensor eyes. NOTE: Test the Safety Sensor Eyes operation by interrupting the eyes while closing the door. Once the sensor eyes are "Learned" and it becomes necessary to remove the sensors, the sensors will need to be "unlearned" by setting DIP switch to "Timer to Close" mode and pressing the Close Button.
CPS-LN4 Wiring Connections for use with LGO Operator
IR PROTECTOR ONLY IR PROTECTOR AND SAFETY EDGE
Important Note: When sensors (IRs) are used, wiring mode B2 must be reprogrammed. See LGO owner's manual for further information.
4
CPS-N4 Wiring Connections for use with LiftMaster Operators Featuring Estate Series X3 or B3 Control Board
CPS-N4 Wiring Connections for use with LiftMaster Operators Featuring GL Control Board
5
Testing the Protector System®
WARNING
Without a properly working CDO Commercial Protector System , persons (particularly children) could be SERIOUSLY INJURED or KILLED by a closing garage door. [. . . ] . 50-15515
CPS-N4 / CPSII-N4 / CPS-LN4
How to Order Repair Parts
Our large service organization spans America. Monday through Saturday When ordering repair parts, please supply the following information: PART NUMBER DESCRIPTION MODEL NUMBER Address orders to: THE CHAMBERLAIN GROUP, INC. Country Club Road Tucson, Arizona 85706
7
01-16013K
© 2005, The Chamberlain Group, Inc. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE LIFT-MASTER CPSII-N4
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LIFT-MASTER CPSII-N4 will begin.