If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LIFT-MASTER 71-REDGRN-HCT. We hope that this LIFT-MASTER 71-REDGRN-HCT user guide will be useful to you.
Manual abstract: user guide LIFT-MASTER 71-REDGRN-HCT
Detailed instructions for use are in the User's Guide.
[. . . ] RED/GREEN LIGHT MODIFICATION
FOR MODEL 71-REDGRN-HCT
FUNCTION
When the door is in motion, the timer circuit will activate the red lamp holder and remain illuminated until door reaches open or closed position. When the door reaches the full open position, the timer circuit will activate the green lamp holder and will remain illuminated based on timer setting. [. . . ] Mount the relay assembly on the pem studs in the electric box using the locknuts (4) provided. Mount the auxiliary limit switches using existing switch hardware; note that the auxiliary limit switches are mounted on top of the existing limit switches. NOTE: If actuator on existing switches has been bent for adjustment, it may be necessary to bend actuator arms on new switches. Figure 2
Relay Assembly
Auxillary Limit Switches
Timer (Shown From Outside Box)
Figure 3
0. 15 Diameter (#25 Drill Size)
1"
4-5/8"
2-1/4" Top of Box
3-11/16" 1/2" 1. 5" (8) Holes 0. 15 Diameter (#25 Drill Size)
Top of Box
4"
1/2"
1"
Top of Box Knockout for Conduit
1-1/2" 0. 15 Diameter (#25 Drill Size)
2
WIRING
WIRE CONNECTIONS FROM RELAY ASSEMBLY
NOTE: The following wires are provided from the factory pre-wired to relay K1 & K2. Connect white wire from relay (K1-1) to white wire coming from red socket in light box with wire nut. Connect white wire from relay (K1-2) to white wire coming from green socket in light box with wire nut. Connect red wire from relay (K1-8) to 115 Vac input power with wire nut. Connect grey wire from relay (K2-7) to 115 Vac input power with wire nut. WIRING CHART LOOSE WIRES
WIRE DESCRIPTION CONNECTION TO BE MADE
Wire, 3" Yellow 3/16" Faston x 3/16" Faston Wire, 28" Yellow 3/16" Faston x 1/4" Strip
Aux. Close Limit (COM) Incoming Neutral
WIRE CONNECTIONS FROM RELAY ASSEMBLY
WIRE DESCRIPTION PREWIRED TO RELAY CONNECTION
Wire, 6" Grey 2 x 3/16" Faston Wire, 6" Grey 2 x 3/16" Faston Wire, 26" Grey 3/16" Faston x 1/4" Strip Wire, 26" White 3/16" Faston x 1/4" Strip Wire, 26" White 3/16" Faston x 1/4" Strip
K1-6 K1-5 K2-7 K1-1
K1-2
WIRE CONNECTIONS FOR LOOSE WIRES
NOTE: The following wires are provided from the factory in the hardware bag. Connect yellow wire from auxiliary open switch (COM) NEUTRAL input with wire nut. Connect yellow wire from auxiliary open switch (NC) to auxiliary close switch (COM). [. . . ] c) When the door reaches the closed position, the timer circuit will activate the red lamp holder and will remain illuminated based on timer setting.