User manual LIFT-MASTER 50HERK
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LIFT-MASTER 50HERK. We hope that this LIFT-MASTER 50HERK user guide will be useful to you.
Manual abstract: user guide LIFT-MASTER 50HERK
Detailed instructions for use are in the User's Guide.
[. . . ] HERKULES MOTION DETECTOR
QuickStart
FUNCTION
The Herkules Motion Detector is a microwave sensor sending out a high frequency sound wave while listening for bounce back. [. . . ] If settings need to be changed refer to manufacturer's instructions. . Medium detection (detects very slow objects) Separation People and Vehicles . . Forward (movement toward the detector) NOTE: If other settings are desired, then they can be changed by using the optional remote control or with the internal push buttons in the detector.
Y X
snottuB gnimmargorP
ADDRESSING THE SENSOR
This assists in programming and reduces interference if multiple units are used on the same location. Address Address 1 Address 2 Address 3 Address 4 Switch 1 Off On Off On
O N
Switch 2 Off Off On On
12
3. Press "Y" button for the desired height: 2 times for 8' to 9. 5' 3 times for 9. 5' to 12. 5' 4 times for 12. 5' to 16' 5 times for 16' to 19' 6 times for 19' to 22. 5' 7 times for 22. 5' to 23' With (optional) remote: 1. Press "F" and then press the following number to set the height: #2 once for 8' to 9. 5' #3 once for 9. 5' to 12. 5' #4 once for 12. 5' to 16' #5 once for 16' to 19' #6 once for 19' to 22. 5' #7 once for 22. 5' to 23' 4. [. . . ] If the button flashes, then the sensor did not accept the program.
Address 1
Address 2
O N
12
Address 3 Address Dip Switch Address 4
O N
12
O N
12
MECHANICAL OPERATOR
24 VAC AC/DC 24 VAC AC/DC
Herkules Microwave Sensor
Pink Red
Brown
White
1 Open
2
3
4
5
6
7 10 L1 L2 L3
LOGIC OPERATOR
LOGIC 3 TERMINAL STRIP
White Brown 14 24 VAC AC/DC 13 24 VAC AC/DC 12 11 10 9 Red 8 7 Open 6 Pink 5 4 Com 3 2 1
LOGIC 2 TERMINAL STRIP
White Brown 13 24 VAC AC/DC 12 24 VAC AC/DC 11 10 9
Herkules Microwave Sensor
OR
Com
Red
8 7 Open 6 5 4 Com 3 2 1
Pink
01-32999
© 2005, The Chamberlain Group, Inc. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE LIFT-MASTER 50HERK
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LIFT-MASTER 50HERK will begin.