[. . . ] RED/GREEN LIGHT CONTROL KIT
FOR USE WITH APT, T, GT, AND LOGIC OPERATORS MODEL RDGRNCARD
WARNING
To prevent possible SERIOUS INJURY or DEATH from electrocution, disconnect electric power to operator BEFORE installing. ALL electrical connections MUST be made by a qualified individual.
WARNING
Step 3
INSTALLATION
MOUNT THE LIGHT BOX STEP 1: Attach mounting bracket to the electrical box with the self-threading screws (2) provided. [. . . ] · Connect white wire to L1 (NEUTRAL) on the power terminal strip. · Connect black jumper from L2 (HOT) on the power terminal strip to (120V IN) terminal on the Red/Green Light Control Module connector.
STEP 6: Install red and green lightbulbs (not provided). Maximum wattage should not exceed 75 watts.
Figure 1
Green Lights Light Box Red
120V IN
24 VOLT DC Terminals
K2 D2 Q2 R4 TB1 3
OUT
+5V +24V
RED LT.
R7
d Re
White Bla ck Cable White Black
TB2 1
3
R6
R1
R8
R9
13
+
J1
10
C2
8
R5
4
1
Green Light
Red Light
OPTIONAL MID-STOP PROGRAMMING:
LOGIC 3 To Program open or down (close) Mid-Stop: 1. Open the door to set close Mid-Stop or close door to set open Mid-Stop. Press the OPEN button for open Mid-Stop, wait until the door reaches the desired Mid-Stop height, then press the STOP button. OR Press the CLOSE button for down Mid-Stop, wait until the door reaches the desired Mid-Stop height, then press the STOP button. Turn selector dial back to desired wiring type.
SET
ON
LOGIC 2 MID-STOP 12 3 4 To Program open Mid-Stop: OFF 1. The door will now stop at this height every time the door is opened.
2
L1
K1
R8
R3
C1
Q3
LOAD
D1
L2
2 R2 Q1 1
GREEN LT.
+24VDC
Light Box
D4
D3
WARNING DEVICES MODULE
LIGHT CONTROL MODULE OPERATION
The green lights on the option board will turn on if the board is seated properly and the power is on. When the door reaches the full open position or programmed mid-stop, the timer circuit will be activated. If the timer has not been set, the red lampholder will receive power when the door starts to close and until close limit is activated. [. . . ] Up Mid-Stop disabled Down Mid-Stop disabled
Down Mid-Stop
D1
Down Mid-Stop disabled
T, TS, FSTS
Stop movement, wait for user input: 3-Button Control Station will OPEN or CLOSE on command Single Button Control/Radio will OPEN on command. If timer to close set is set for up Mid-Stop, timer to close will close the door.
Stop movement, then count down timer to close timer & auto close OR User input during timer to close countdown: 3-Button Control Station will OPEN the door, CLOSE the door, or STOP the countdown Single Button Control will CLOSE on command Radio will OPEN on command Red/Green enabled at Mid-Stop
Failsafe B2, Failsafe C2 Stop movement, wait for user input: 3-Button Control Station will OPEN or CLOSE on command Single Button Control/Radio will OPEN open command Failsafe D1 Up Mid-Stop disabled
Down Mid-Stop disabled
Down Mid-Stop disabled
Failsafe E2
Stop movement, wait for user input: 3-Button Control Station will OPEN or CLOSE on command